Home> Company News> How to Read a PAC Certificate of Analysis Before Ordering

How to Read a PAC Certificate of Analysis Before Ordering

2026,11,28
A certificate of analysis (COA) is the document that ties a delivered batch to the specification you bought. In practice, many buyers receive a PDF with a company letterhead, a table of numbers, and a stamp, and file it without reading it. That is where disputes begin three weeks later, when the plant's dosing no longer produces the same effluent quality and nobody can prove what was delivered.
This is the reading order we apply to a PAC COA before releasing an order. It takes about ten minutes per batch and it answers the questions an importer will be asked by a customer, an auditor or a customs laboratory.
1. A COA belongs to a batch, a TDS belongs to a product
The first distinction to fix is between the two documents. The technical data sheet describes the grade: what the product is, its typical values, packaging, storage and applications. The certificate of analysis describes one production batch: what was actually measured, on which date, by which method.
So a COA with no batch number is not a COA; it is a specification sheet with numbers. A COA that carries the same batch number across three shipments is a warning, not a convenience. And a COA issued for "PAC 30%" does not automatically cover the "PAC 28%" you ordered, even from the same factory, because the two are different production grades with different control limits.
2. Read the identity block before the numbers
Check five fields in this order: product name and model as ordered, grade or standard claimed, batch or lot number, production date, and test date. The test date should fall after the production date and before shipment; a test date several months before the production date means the certificate was prepared for a different batch. Confirm that the grade named on the COA matches the grade on the contract, the packing list and the bag label. Mismatches here are the most common cause of claims that could have been avoided at the desk.
3. Know which basis the results are reported on
This is the technical heart of reading a PAC COA, and it is where buyers most often misjudge a batch.
GB/T 22627-2022 specifies limits for insoluble matter, iron, ammonia nitrogen, arsenic, lead, cadmium, mercury and chromium on the basis of an Al₂O₃ content of 10%. When the actual Al₂O₃ content differs from 10%, the results are converted to the 10% basis before they are compared with the standard. A COA that reports arsenic at 0.0004% without stating whether that figure is as-measured or converted to the 10% basis cannot be checked against the limit, and a laboratory reviewing it will reject it.
Ask the supplier to state the basis on the certificate. If the certificate does not, ask for the calculation. This is a document question, not a negotiation: a supplier who cannot explain the basis does not have a controlled process behind the paper.
4. Units and elements: three conversions worth memorising
Percent and milligrams per kilogram are the same measurement at different scale: 1% is 10,000 mg/kg. A limit written as 0.0005% is 5 mg/kg, and a laboratory report in mg/kg is normal for trace metals.
Aluminium and aluminium oxide are not interchangeable. Al₂O₃ equals Al multiplied by approximately 1.889. A product described as "16% Al" is not a "16% Al₂O₃" product; on an oxide basis it is close to 30%. When a data sheet mixes the two, an offer can look dramatically cheaper or dearer than it is.
Basicity is reported as a percentage of the hydroxyl-to-aluminium ratio, not as an Al₂O₃ figure. A basicity of 70% does not mean 70% Al₂O₃, and offers must be compared within the same basicity band.
5. Each result should carry a method
A number without a method cannot be arbitrated. For PAC the usual references are the clauses of GB/T 22627-2022: Al₂O₃ by titration, basicity by the specified method, insoluble matter by filtration and gravimetry, pH on a 10 g/L solution, and the metals by atomic absorption or inductively coupled plasma techniques. If your market requires a different method, say so in the purchase order, because methods differ in detection limits and a compliant batch can look non-compliant when tested another way.
6. Distinguish a limit from a measurement
"≥ 28.0%" is a specification limit. "28.6%" is a measured result. Good certificates show both, and a good buyer reads both. A batch that reports exactly the minimum on every indicator, batch after batch, suggests the certificate is being written to the limit rather than produced from the analysis. A batch that reports a comfortable margin above the minimum, with a method reference and a signature, is the one that behaves predictably in the plant.
7. Compare batches, not just the one in front of you
Ask for three consecutive certificates for the grade you buy. Look at the spread, not the average. A stable Al₂O₃ and basicity across batches means a controlled process and a predictable dose. A drift of several points in basicity between batches means your jar test result this month will not repeat next month, and your operator will compensate by adding more chemical.
8. Factory certificate versus third-party report
For industrial wastewater use, a factory COA is normally sufficient documentation. For drinking-water grade product, or for a market where the importer must register the chemical, a certificate from an accredited third-party laboratory is often required, and the factory's own certificate may not be accepted in its place. Confirm the requirement with your importer or authority before the order, not after the container sails.
9. The twelve-line check
# Check Acceptable answer
1 Product and model match the order Exact match on name, grade and model
2 Standard or grade claimed GB/T 22627-2022, GB 15892-2020, or the contract spec
3 Batch number present Unique, traceable to the bag label
4 Production and test dates Test after production, both before shipment
5 Al₂O₃ result and its basis Value, method clause, basis stated
6 Basicity result Within the agreed band, method stated
7 Insoluble matter Within the limit of the grade
8 pH of 10 g/L solution Within 3.5–5.0 for standard PAC
9 Iron content Within the limit your application allows
10 Heavy metals As, Pb, Cd, Hg, Cr reported with limits
11 Reporting basis Converted to 10% Al₂O₃ basis, stated
12 Signature, stamp, laboratory identity Present and consistent with the supplier
 
10. Red flags that stop an order
A certificate with no batch number. One certificate reused across shipments. Heavy-metal lines missing on a drinking-water grade offer. Results reported in percent for trace metals without a basis. A model name on the certificate that differs from the model you ordered. And a "qualified" or "complies" conclusion with no measured values — that is a statement of opinion, not an analysis.
Send us the specification and we will send the file
Tell us the grade you need, the indicators that must appear, the standard your market applies and the destination. We will send the matching TDS and a batch certificate for your review before the order is placed, and we will state the reporting basis on the file, so your laboratory and your importer can check it without a second round of emails.
Contact Us

Author:

Ms. Amy

Phone/WhatsApp:

+86 15161663213

Popular Products
You may also like
Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be between 20-8000 characters

Contact Us

Author:

Ms. Amy

Phone/WhatsApp:

+86 15161663213

Popular Products
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send

Manage Your Cookies

Necessary cookies are always enabled. You can turn off other cookie options. Cookie Policy and Privacy Policy.

To use chat support services, please enable support cookies.

Strictly Required Cookies

Off

These cookies are required for the website to run and cannot be switched off. Such cookies are only set in response to actions made by you such as language, currency, login session, privacy preferences. You can set your browser to block these cookies but this might affect the way our site is working.

Analytics and Statistics

Off

These cookies allow us to measure visitors traffic and see traffic sources by collecting information in data sets. They also help us understand which products and actions are more popular than others.

Marketing and Retargeting

Off

These cookies are usually set by our marketing and advertising partners. They may be used by them to build a profile of your interest and later show you relevant ads. If you do not allow these cookies you will not experience targeted ads for your interests.

Functional Cookies

Off

These cookies enable our website to offer additional functions and personal settings. They can be set by us or by third-party service providers that we have placed on our pages. If you do not allow these cookies, these or some of these services may not work properly
CLOSE ACCEPT SELECTED COOKIES

We've updated our Terms of Service and Privasy Policy, to better explain our service and make it more understandable. By continuing to see this site, you agree to our updated Terms of Service and Privacy Policy. We use cookies to improve and personalize your browsing experience. By clicking "Accept Ceokies", you accept our use of cookies in accordance with our Cookie Policy.