Two buyers can send us the same one-line request — "price for PAC, 20 tonnes" — and receive two offers that cannot be compared. One is a liquid at a stated Al₂O₃ content, the other a powder at a different content, in different packaging, with different unloading and dissolving costs. The number that looks cheaper per tonne is often the more expensive per unit of active ingredient.
This checklist is the sequence we use when a buyer asks us to quote both forms of polyaluminium chloride (PAC). It is written for the purchasing side, not the laboratory, and every item can be answered from documents or from a short call with the plant.
1. Convert both offers to the same Al₂O₃ basis
This is the single step that decides most liquid-versus-powder questions, and it is the step buyers most often skip.
GB/T 22627-2022, the Chinese national standard for water treatment grade PAC, sets a minimum Al₂O₃ content of 8.0% for liquid product and 28.0% for solid product. Drinking-water grade PAC under GB 15892-2020 is specified higher, at 10.0% liquid and 29.0% solid, with a basicity range of 45–90% and tighter heavy-metal limits. Whatever figures your supplier quotes, they must sit on the same basis before you compare them.
The calculation is simple. Divide the price per tonne of product by the Al₂O₃ fraction:
Cost per tonne Al2O3  =  price per tonne of product  ÷  Al2O3 fraction
A liquid at 10% Al₂O₃ takes 10 tonnes of product to deliver one tonne of Al₂O₃. A solid at 30% takes 3.33 tonnes. If the liquid is offered at a price that is less than one third of the solid, the liquid is the cheaper source of active ingredient before freight; if it is more than one third, the solid wins. Add freight per tonne of product to each side, and the picture usually changes again, because you are shipping water in the liquid case.
Two more comparability traps sit inside this step. First, basicity: the standard permits a wide range, and a low-basicity and a high-basicity product do not behave the same way in coagulation. Compare offers only within the same basicity band. Second, iron: check the Fe limit you actually need, particularly if the effluent is discharged to a sensitive receiving water or the product is for potable use.
2. Check what arrives at your gate
Legal net weight, not nominal volume, is what you pay for. A 1000 litre IBC of liquid PAC at the standard minimum density of 1.12 g/cm³ holds at least about 1.12 tonnes; a denser product holds more. Ask for the net weight per package, the tare weight, and whether IBCs are one-way or returnable. Check the discharge arrangement — top valve, bottom valve, or pump — because it decides how your operator empties the container.
For solid PAC the common packages are 25 kg woven bags and 500–1000 kg jumbo bags. Confirm whether there is an inner liner, whether the bag is UV-stabilised, pallet dimensions, and stack height. A jumbo bag needs a hoist or a forklift with a bag-lifting frame; if your warehouse has neither, the "cheaper" solid option acquires a handling cost the day it lands.
3. Compare the dissolving and dosing side, not just the chemical
Solid PAC has to be dissolved before dosing. In most plants this means a dissolution tank with an agitator, a working solution of roughly 5–10% (read the figure from the TDS of the grade you buy), a settling period, and a strainer ahead of the dosing pump, because the standard allows up to 0.4% water-insoluble matter. That insoluble fraction does not disappear; it accumulates in the tank and has to be drained and cleaned on a schedule. There is also dust at the feeding point, which means respiratory protection and a clean filling area.
Liquid PAC removes the dissolving labour and the dust, but it is acidic (the standard specifies pH 3.5–5.0 for a 10 g/L solution) and needs corrosion-resistant tanks, lines and dosing pumps. Dilution water quality matters: high-hardness or high-turbidity dilution water can cause precipitation in the day tank.
The trade-off is straightforward. If your plant runs continuously, has limited labour, or has no space for a dissolution tank, liquid is usually the better operational fit. If your site is far from the port, storage space is tight, or the product may sit for months, the solid form's concentration per tonne and longer shelf stability usually outweigh the handling.
4. Storage and climate
Liquid PAC has a freezing risk. Ask the supplier for the crystallisation or storage-temperature statement for the exact grade, keep storage above that limit, and plan insulation or a heated store if your winter is severe. Solid PAC is hygroscopic: kept dry, sealed and off the floor it is stable; exposed to humid air it cakes, and caked powder dissolves into lumps that block strainers and under-dose the plant.
Shelf life is a document question, not a rule of thumb. Ask for the shelf life stated on the TDS of the specific grade, insist on a batch number and production date on every delivery, and run first-in-first-out in the warehouse.
5. Documents to request before you compare
Document What it must show Why it decides the comparison
TDS, liquid grade Al₂O₃ %, basicity %, density, pH, Fe, packaging, storage Gives the basis for the price conversion and the dosing design
TDS, solid grade Al₂O₃ %, basicity %, insoluble %, dissolution guidance Confirms whether your tank and strainer can handle the product
COA, one batch per form Batch no., test date, Al₂O₃, basicity, insoluble, heavy metals, methods Proves the two offers are the same quality, not just the same name
SDS Hazard classification, PPE, storage, spill handling Drives site permits and operator training
Packaging specification Net weight, liner, pallet, stack height Converts a product price into a landed cost
 
6. The quote comparison sheet
Ask each supplier to complete the same six lines. A quote that cannot fill them is not comparable yet.
Field Supplier A Supplier B Note
Form and grade Liquid or solid; industrial or drinking-water grade
Al₂O₃ % and basicity % Same basis, same basicity band
Price per tonne product and per tonne Al₂O₃ Include the conversion in the offer
Package, net weight, units per 20 ft container 20 ft payload limit decides the real freight per tonne
Destination port and Incoterm FOB, CFR or CIF changes what you are comparing
Documents supplied with shipment COA of the actual batch, SDS, packing list
 
7. Four mistakes we see every month
Comparing a 28% solid against a 10% liquid at face price. Choosing on colour or on a single test result rather than on a jar test with your own water. Accepting a liquid figure that is not clearly labelled as Al₂O₃ — a "16%" number means nothing until you know whether it refers to Al₂O₃, to aluminium, or to dry matter, and a parameter conflict of this kind has to be resolved against the COA and TDS before anyone orders or publishes it. And forgetting the receiving plant's limit on iron or heavy metals, which can rule out an otherwise cheaper grade.
Get a like-for-like comparison
Send us your flow rate or monthly consumption, the form you use today, your dosing practice, the discharge limits you must meet, the destination port and the Incoterm you buy on. We will return both forms converted to the same Al₂O₃ basis, with packaging, freight assumptions and the documents that come with each option, so the decision is made on landed cost per tonne of active ingredient rather than on the price on the first line of the offer.
Contact Us

Author:

Ms. Amy

Phone/WhatsApp:

+86 15161663213

Popular Products
You may also like
Related Categories

Email to this supplier

Subject:
Email:
Message:

Your message must be between 20-8000 characters

Contact Us

Author:

Ms. Amy

Phone/WhatsApp:

+86 15161663213

Popular Products
We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

Send

Manage Your Cookies

Necessary cookies are always enabled. You can turn off other cookie options. Cookie Policy and Privacy Policy.

To use chat support services, please enable support cookies.

Strictly Required Cookies

Off

These cookies are required for the website to run and cannot be switched off. Such cookies are only set in response to actions made by you such as language, currency, login session, privacy preferences. You can set your browser to block these cookies but this might affect the way our site is working.

Analytics and Statistics

Off

These cookies allow us to measure visitors traffic and see traffic sources by collecting information in data sets. They also help us understand which products and actions are more popular than others.

Marketing and Retargeting

Off

These cookies are usually set by our marketing and advertising partners. They may be used by them to build a profile of your interest and later show you relevant ads. If you do not allow these cookies you will not experience targeted ads for your interests.

Functional Cookies

Off

These cookies enable our website to offer additional functions and personal settings. They can be set by us or by third-party service providers that we have placed on our pages. If you do not allow these cookies, these or some of these services may not work properly
CLOSE ACCEPT SELECTED COOKIES

We've updated our Terms of Service and Privasy Policy, to better explain our service and make it more understandable. By continuing to see this site, you agree to our updated Terms of Service and Privacy Policy. We use cookies to improve and personalize your browsing experience. By clicking "Accept Ceokies", you accept our use of cookies in accordance with our Cookie Policy.